Обновление MikroTik RouterOS v6.42.4
					
				
			
				
			
			
				Производитель MikroTik обновил операционную систему RouterOS до версии 6.42.4.
Прошивку RouterOS версии 6.42.4 можно скачать с сайта http://www.mikrotik.com/download.html
В версии 6.42.4 сделаны следующие улучшения и исправления (15 июня 2018 г.):
- bridge - allow to make changes for bridge port when it is interface list;
 - bridge - fixed FastPath for bridge master interfaces (introduced in v6.42);
 - certificate - fixed "add-scep" template existence check when signing certificate;
 - chr - fixed adding MSTI entries;
 - chr - fixed boot on hosts older than Windows Server 2012 when running CHR on Hyper-V;
 - chr - fixed various network hang scenarios when running CHR on Hyper-V;
 - console - fixed script permissions if script is executed by other RouterOS service;
 - dhcpv4-server - fixed DHCP server that was stuck on invalid state;
 - health - changed "PSU-Voltage" to "PSU-State" for CRS328-4C-20S-4S+;
 - health - fixed incorrect PSU index for CRS328-4C-20S-4S+;
 - ipsec - improved reliability on IPsec hardware encryption for RB1100Dx4;
 - kidcontrol - fixed dynamically created firewall rules order;
 - led - added "dark-mode" functionality for hEX S and SXTsq 5 ac devices;
 - led - fixed CCR1016-12S-1S+ LED behaviour after Netinstall (introduced in v6.41rc58);
 - led - use routers uptime as a starting point when turning off LEDs if option was not enabled on boot;
 - ppp - fixed "hunged up" grammar to "hung up" within PPP log messages;
 - quickset - added missing wireless "channel-width" settings;
 - quickset - added support for "5ghz-a/n" band when CPE mode is used;
 - snmp - added remote CAP count OID for CAPsMAN;
 - snmp - fixed readings for CAPsMAN slave interfaces;
 - supout - added "partitions" section to supout file;
 - usb - properly detect USB 3.0 flash on RBM33G when jumper is removed;
 - userman - improved unique username generation process when adding batch of users;
 - w60g - improved RAM memoy allocation processes;
 - winbox - added missing "dscp" and "clamp-tcp-mss" settings to IPv6 tunnels;
 - winbox - allow to specify full URL in SCEP certificate signing process;
 - winbox - by default specify keepalive timeout value for tunnel type interfaces;
 - winbox - show "scep-url" for certificates;
 - winbox - show "System/Health" only on boards that have health monitoring;
 - winbox - show firmware upgrade message at the bottom of "System/RouterBOARD" menu;
 - wireless - enable all chains by default on devices without external antennas after configuration reset;
 - wireless - improved Nv2 reliability on ARM devices.
 
 
				